AssetStack

Dashboard

Total Assets

1253

Operational

100%

Fleet Health

100%

At Risk

4

Pending Tasks

12

Verified Savings

$77K

Portfolio Briefing

Good afternoon

CRITICAL

27 lots can't hand over yet: 50 blocking snags to clear

98 snags open, 11 safety-critical. 13 work orders in progress, 7 overdue. 9 lots settle in the next 60 days, so clear their snags first. 3 asset alerts waiting, 1 critical.

50 blocking snags7 overdue jobs · 9 settlements due ≤60 days

Generated 12:20 PM

Verified Savings

AUDITED

Independently confirmed financial outcomes

$77K 3.89× ROI

4 verified interventions · $97K in failure costs avoided

Failure cost avoided

$97K

Intervention spend

$20K

Net verified

$77K

Highest-value outcomes

Athena Quays podium terrace waterproofing rectified at subcontractor cost

Post-action inspection

$34K

Athena Quays lift door operators recovered from subcontractor

Post-action inspection

$22K

No.1 Grant Avenue fire brigade attendance charges recovered

Expert review

$17K

Emergency lighting battery renewal bundled across four buildings

Historical comparison

$4K
View full ledger

Fleet Overview

By Status

By Risk

Operational (1249)
Degraded (4)

1253

Total

100%

Health

4

At Risk

Risk by Location

12 locations
New Building
The Landmark — Amenity Podium & Retail
No.1 Grant Avenue — Hope Island
Athena Quays — Hope Island
The Landmark — Tower One
Athena Residences — Hope Island
35 Grant Avenue — Hope Island
Orama — Chevron Island
Ferry Road Showroom — Southport
The Landmark — Tower Two
The Landmark — Towers Three & Four (Future)
The Landmark — Experience Centre
low
medium
high
critical

Fleet Health Trend & Prediction

Day 1Day 2Day 3Day 4Day 5Day 6Day 7Day 8Day 9Day 10Day 11Day 12Day 13Day 140255075100
Actual
Predicted
Threshold

Alerts

3
Acknowledge
Resolve

Sump pump cycling 4x above design frequency

2 months ago

Duty sump pump start count has averaged 212 cycles/day against a design expectation of ~50. Pattern indicates continuous below-grade water ingress rather than pump failure.

Acknowledge
Resolve

Two entrapments in 30 days on a single-lift building

2 months ago

Lift has stopped between floors twice this month with passengers on board. No redundancy available in this building.

Acknowledge
Resolve

Chlorinator output below specification

2 months ago

Free chlorine residual falling below the required range within 6 hours of dosing. Third recurrence in 14 months.

Acknowledge
Resolve

Condenser coil efficiency loss accelerating

2 months ago

Condensing approach temperature has risen 6.2K over 9 months, consistent with advanced coil corrosion for asset age.

Acknowledge
Resolve

Balustrade fixing corrosion — safety critical

2 months ago

Rust staining and measurable bracket movement identified at multiple level 12 balustrade base fixings.

Acknowledge
Resolve

Compressor efficiency below replacement threshold

2 months ago

Rooftop package unit drawing 18% above nameplate current for delivered capacity at 7 years of age.

Equipment Fleet

motor

Car Lift RHS - Visitor Car Park Door / Motor

100
RUL—
Risk
low
Value—
New Building
motor

Car Lift LHS - Visitor Car Park Door / Motor

100
RUL—
Risk
low
Value—
New Building
hvac system

Gym A/C

100
RUL—
Risk
low
Value—
New Building
building

Lounge Sliding Glass Door

100
RUL—
Risk
low
Value—
New Building
motor

Car Lift LHS - Level B2 Door / Motor

100
RUL—
Risk
low
Value—
New Building
pump

Back Wall Garden Sprinkler System

100
RUL—
Risk
low
Value—
New Building
building

Unit 301 - Lights

100
RUL—
Risk
low
Value—
New Building
hvac system

Unit 301 - A/C

100
RUL—
Risk
low
Value—
New Building
fire suppression

Unit 302 - Fire Sprinkler Pipes

100
RUL—
Risk
low
Value—
New Building
building

Unit 306 - Lights

100
RUL—
Risk
low
Value—
New Building
building

Unit 307 - Plumbing Pipes

100
RUL—
Risk
low
Value—
New Building
hvac system

Unit 308 - A/C

100
RUL—
Risk
low
Value—
New Building
hvac system

Unit 402 - A/C Pipes

100
RUL—
Risk
low
Value—
New Building
building

Unit 403 - Walls

100
RUL—
Risk
low
Value—
New Building
building

Rowing Machine

100
RUL—
Risk
low
Value—
New Building
building

Pool Cover

100
RUL—
Risk
low
Value—
New Building
building

Lounge Chairs

100
RUL—
Risk
low
Value—
New Building
hvac system

Car Park Extractor Fans (HVAC)

100
RUL—
Risk
low
Value—
New Building
building

Unit 302 - Carpet

100
RUL—
Risk
low
Value—
New Building
building

Unit 303 - Carpet

100
RUL—
Risk
low
Value—
New Building
building

Unit 304 - Carpet

100
RUL—
Risk
low
Value—
New Building
building

Unit 307 - Walls

100
RUL—
Risk
low
Value—
New Building
building

Unit 308 - Walls

100
RUL—
Risk
low
Value—
New Building
building

Unit 309 - Carpet

100
RUL—
Risk
low
Value—
New Building